Compaq 1850R Server User Manual


 
E-4 Switches and Jumpers
Writer: Michele Wray Project: Compaq ProLiant 1850R Setup and Installation Guide Comments: 333172-002
File Name: L-appe.doc Last Saved On: 12/14/98 4:21 PM
COMPAQ CONFIDENTIAL - NEED TO KNOW REQUIRED
NIC Operating Mode
The ProLiant 1850R server comes standard with the Compaq Netelligent 10/100
TX embedded controller. The controller automatically differentiates between
the 10Mb and 100Mb environments when the RJ-45 connector is used.
SCSI Device Jumper Settings
No two SCSI devices connected to the same SCSI controller can have the same
SCSI ID. If another SCSI device is connected to the same controller, check its
SCSI ID in the Compaq System Configuration Utility before beginning the
installation procedure for this additional drive. The SCSI ID is set by jumpers
ID 2, ID 1, and ID 0 located on each SCSI device.
The following chart provides the SCSI ID jumper settings for Compaq SCSI
hard drives.
Table E-3
SCSI Device Jumper ID Settings
SCSI ID Bit 2 Bit 1 Bit 0
6
ON ON OFF
5
ON OFF ON
4
ON OFF OFF
3
OFF ON ON
2
OFF ON OFF
1
OFF OFF ON
0
OFF OFF OFF