Emerson 752I Computer Hardware User Manual


 
Monitor: Other Commands
Katana®752i User’s Manual 10006024-04
15-22
frusetuser
The frusetuser command writes count bytes to offset in the FRU user area and copies the
bytes to storage.
Definition:
frusetuser offset count storage
gethvr
The gethvr command returns the contents of the Hardware Version Register (see Register
Map 6-7 on page 6-4).
Definition:
gethvr
getmonver
The getmonver command prints the monitor version string of the currently running moni-
tor (default). Specifying the optional socket or soldered parameter prints the version string
for the corresponding device.
Definition:
getmonver
getpcimemsize
The getpcimemsize command shows the maximum memory window size (starting at the
base) that is accessible from a device on PCI/cPCI.
Definition:
getpcimemsize
Example: =>getpcimemsize
PCI Memory Size Parameters:
---------------------------
PCI Memory Size: 0x08000000 (134217728)
CPCI Memory Size: 0x01000000 (16777216)
Current Settings for PCI Memory Size Are:
---------------------------
PCI CS0: 0x07FFF000 (134213632)
PCI CS1: 0x00000000 (0)
PCI CS2: 0x00000000 (0)
PCI CS3: 0x00000000 (0)
---------------------------
CPCI Enabled
cPCI CS0: 0x00FFF000 (16773120)
cPCI CS1: 0x00000000 (0)
cPCI CS2: 0x00000000 (0)
cPCI CS3: 0x00000000 (0)
---------------------------