Emerson 752I Computer Hardware User Manual


 
IPMI Controller: IPMI Message Protocol
10006024-04 Katana
®
752i User’s Manual
11-13
Response
Data
(continued)
4 Present Threshold Comparison Status
For threshold-based sensors:
Bits[7:6], Reserved. Returned as 1 (binary). Ignore on read.
Bit[5], 1=at or above (ε) upper non-recoverable threshold
Bit[4], 1=at or above (ε) upper critical threshold
Bit[3], 1=at or above (ε) upper non-critical threshold
Bit[2], 1=at or below (δ) lower non-recoverable threshold
Bit[1], 1=at or below (δ) lower critical threshold
Bit[0], 1=at or below (δ) lower non-critical threshold
For discrete reading sensors:
Bit[7], 1=state 7 asserted
Bit[6], 1=state 6 asserted
Bit[5], 1=state 5 asserted
Bit[4], 1=state 4 asserted
Bit[3], 1=state 3 asserted
Bit[2], 1=state 2 asserted
Bit[1], 1=state 1 asserted
Bit[0], 1=state 0 asserted
5 For Discrete Reading Sensors Only (optional, otherwise 0x00)
Bit[7], Reserved. Returned as 1 (binary). Ignore on read.
Bit[6], 1=state 14 asserted
Bit[5], 1=state 13 asserted
Bit[4], 1=state 12 asserted
Bit[3], 1=state 11 asserted
Bit[2], 1=state 10 asserted
Bit[1], 1=state 9 asserted
Bit[0], 1=state 8 asserted
Type: Byte: Data Field: (continued)