Epson 2170 Printer User Manual


 
A.2 EEPROM ADDRESS MAP
Address Data Data Format Default
00H, 01H Reserved 0000H
Area 1
02H, 03H Character table
selection
0: PC437 1: PC850 2: PC860
3: PC863 4: PC865 5: PC861
6: BRASCII 7: Abicomp 8: ISO Latin 1
9: Roman8, 10: PC437Greek 11: PC852
12: PC853 13: PC855 14: 857
15: — 16: PC866 17: PC869
18: ISOLatin1T 19: ISO8859-7 20: MAZOWAI
21: Code MJK 22: Bulgaria 23: Estonia
24: PC774 25: ISO Latin2 26: PC866 LAT.
0000H
(PC437)
04H, 05H Page length
for rear tractor
1 to 22 x 432 (in units of 1/432 inch), 0000H:
11 inches (same as default)
1290H
(11")
06H, 07H Page length for
front tractor
1 to 22 x 432 (in units of 1/432 inch), 0000H:
11 inches (same as default)
1290H
(11")
08H, 09H Page length
for CSF bin 1
1 to 22 x 432 (in units of 1/432 inch), 0000H:
22 inches (same as default)
2520H
(22")
0AH, 0BH Page length
for CSF bin 2
1 to 22 x 432 (in units of 1/432 inch), 0000H:
22 inches (same as default)
2520H
(22")
0CH, 0DH TOF adjustment
value for rear
tractor
–72 to 432 (4.2 mm to 8.5 mm + 1 inch,
in units of 1/432 inch)
0000H
(8.5 mm)
0EH, 0FH TOF adjustment
value for front
tractor
–72 to 432 (4.2 mm to 8.5 mm + 1 inch,
in units of 1/432 inch)
0000H
(8.5 mm)
10H,11H TOF adjustment
value for front
CSF bin1
–72 to 432 (4.2 mm to 8.5 mm + 1 inch,
in units of 1/432 inch)
0000H
(8.5 mm)
12H,13H TOF adjustment
value for front
CSF bin2
–72 to 432 (4.2 mm to 8.5 mm + 1 inch,
in units of 1/432 inch)
0000H
(8.5 mm)
14H,15H TOF adjustment
value for rear
manual insertion
–72 to 432 (4.2 mm to 8.5 mm + 1 inch,
in units of 1/432 inch)
0000H
(8.5 mm)
16H,17H TOF adjustment
value for front
manual insertion
–72 to 432 (4.2 mm to 8.5 mm+1 inch, in units
of 1/432 inch
0000H
(8.5 mm)
18H,19H Bottom margin for
front tractor
1 to 22 x 432 (in units of 1/432 inch), 0000H:
11 inches (same as default)
1290H
(11")
1AH,1BH Bottom margin for
rear tractor
1 to 22 x 432 (in units of 1/432 inch),
0000H:11inches (same as default)
1290H
(11")
1CH Front selection 0: Roman, 1: Draft , 2: Sans serif 00H
(Roman)
1DH Pitch selection 0:10 cpi, 1: 12 cpi, 2: 15 cpi, 3: 17 cpi,
4: 20 cpi, 5: Proportional
00H
(10 cpi)
Assignment of data for two or more bytes is sequential: from lower byte to lower address, and
from higher byte to higher address.
Appendix FX-2170 Service Manual
A-2 Rev.A