IBM CTI 2572 Network Card User Manual


 
CTI 2572 Installation and Operation Guide
105
HEX DEC DESCRIPTION SOLUTION
239B 9115 NETWORK READ ERROR
The module detected an error when reading
for the Ethernet port
This may be caused by an intermittent
network condition. Retry the operation. If the
condition persists try replacing the module to
determine if the condition will disappear.
If replacing the module does not improve the
condition, you should test your network
thoroughly.
239C 9116 NETWORK WRITE ERROR
The module was unable to write data to the
TCP/IP socket.
The usual cause of this problem is a lost
connection due to network problems or a
failure in the remote node. Recovery is the
responsibility of the remote node.
239D 9117 COMMAND TIMEOUT
The protocol manager timed out before
completing the command.
Retry the command.
If the timeout error persists, try increasing the
value for command timeout.
If the timeout error continues to occur, the
remote device may not be available or there
may not be a network connection to the
remote device. Correct the condition and
retry.
239E 9118 PROTOCOL MANAGER BUSY
The protocol manager received a new
command prior to completing the previous
command.
You can cause this error by using two
command slots to send concurrent commands
to the same connection number.
Dont do this.
239F 9119 INVALID CONNECTION NUMBER
The command block contained an invalid
connection number.
Change the connection number in the
command block to a valid number. See the
documentation on the specific command
block.
23A0 9120 BAUD RATE SELECTION ERROR
(Serial Ports Only)
The protocol manager was passed an invalid
baud rate. Valid baud rates are 75, 110, 150,
300, 600, 1200, 2400, 4800, 9600, and
19200.
The error is caused by an incorrect value in
the command block for the Create Connection
command. Check the value and correct any
entry errors.
Ensure that the Command Slot points to the
correct command block.
23A1 9121 DATA BITS SELECTION ERROR
(Serial Ports Only)
The protocol manager was passed an invalid
value for data bits. Valid data bit values are 5,
6, 7, and 8.
See error code 23A0
23A2 9122 PARITY SELECTION ERROR
(Serial Ports Only)
The protocol manager was passed an invalid
parity value. Valid parity values are 0-None,
1-Odd, 2-Even.
See error code 23A0