IBM CTI 2572 Network Card User Manual


 
CTI 2572 Installation and Operation Guide
61
!WX2.3 C15
219 [-] [---------------------------------------------------------------(RST )
If Cmd Err bit TRUE, it indicates error occurred when executing the Send
Command. Store error, set C108 (Error flag), and C108 (Err Ack) bits.
! C15 WX2.1 MOVW5---------+ C108
225 [-]/[---] [---! !-------------------------------------*-(SET )
! ! A:V140 ! !
! ! B:V1410 ! ! WY4.1
! ! N=1 ! +-( )
! +-------------+
!
This rung executes when the Send Command has completed without errors and the
Receive input (X3) is TRUE. Logic sets Recv Cmd (C14) sequence and clears
C13 (Send Cmd Seq Active).
! C15 WX2.3 WY4.3 C108 X3 C13
239 [-]/[---]/[---]/[---]/[---] [-------------------------------------*-(RST )
! !
! ! C14
! +-(SET )
!
This rung executes when the Send Command has completed with error or when the
Receive Input (X3) is FALSE. Logic sets C15 (Send Cmd Enable) to retry Send
Cmd and clears C108 (Cmd Error).
! C15 WY4.3 WX2.3 X3 C15
254 [-]/[---]/[---]/[-*-]/[-------*-----------------------------------*-(SET )
! ! ! !
! !C108 WY4.1! ! C13
! +-] [---]/[-+ [-(RST )
! !
! ! C108
! +-(RST )
!
Skips over logic section EXCEPT when executing Send Command sequence.
! LBL12
277 [-------------------------------------------------------------------( )
!
S7 Configuration
Note:
This manual assumes you are familiar with the S7 system, including installing and configuring the
CP343-1 Ethernet TCP/IP module, and using the Step 7 software develop application programs. If
you have questions about the S7 and related components, please contact your Siemens technical
representative.
Using the Step7 configuration program, create an Ethernet subnet consisting of the S7 PLC with a
CP343-1 module and an Other Station named CP2572. Since there is no router on this network, set
the subnet default to No Router. Then, selecting Standard Router under the individual node
network properties will automatically select no router.