Intel SE7520JR2 Computer Hardware User Manual


 
Intel® Server Board SE7520JR2 Platform Management
Revision 1.0
C78844-002
137
down, power cycle, and/or reset actions, the actions are performed according to PEF Action
Priorities.
Note: An action that has changed from delayed to non-delayed, or an action whose delay time
has been reduced automatically has higher priority. The mBMC can be configured to log PEF
actions as SEL events.
Table 54: PEF Action Priorities
Action Priority Delayed Type Note
Power-Down 1 Yes PEF Action
Soft-shutdown 2 Yes OEM PEF Action Not executed if a power-down action was
also selected
Power cycle 3 Yes PEF Action Not executed if a power-down action was
also selected
Reset 4 Yes PEF Action Not executed if a power-down action was
also selected
Diagnostic Interrupt 5 No PEF Action Not executed if a power-down action was
also selected
PET Alert 6 No PEF Action When selected, always occurs immediately
after detection of a critical event.
Sensor feedback 7 No OEM PEF Action When selected, always occurs immediately
after detection of a critical event.
IPMB message event 8 No OEM PEF Action When selected, always occurs immediately
after detection of a critical event.
Fault LED action 9 No OEM PEF Action When selected, always occurs immediately
after detection of a critical event, and is
stopped after the de-assertion of all critical
events that requested LED blinking.
Identification LED action 10 No OEM PEF Action When selected, always occurs immediately
after detection of a critical event.
5.3.18.2 Alert over LAN
LAN alerts are sent as SNMP traps in ASF formatted Platform Event Traps (PET) to a specified
alert destination. The Alert over LAN feature is used to send either PET alerts or directed events
to a remote system management application, regardless of the state of the host’s operating
system.
LAN alerts may be sent over any of the LAN channels supported by a platform. LAN alerts can
be used by PEF to send out alerts to selected destination whenever an event matches an event
filter table entry. For more information on LAN alerts, see the IPMI specifications v1.5
5.3.19 mBMC Sensor Support
The following tables are for the built-in and the external sensors for the platform. There is a
management controller locator record as a built-in SDR besides the given below.