![](http://pdfasset.owneriq.net/f/ce/fce384a3-9d36-47e0-b26a-8f8f89c414f3/fce384a3-9d36-47e0-b26a-8f8f89c414f3-bg91.png)
Intel® Server Board SE7520JR2 Platform Management
Revision 1.0
C78844-002
145
Sensor Name
Sensor
Number
Sensor Type
Event /
Reading
Type
Event Offset
Triggers
Assert /
Deassert
Readable
Value /
Offsets
EventData
Rearm
Standby
Digital Fan 10 59h
Fan
04h
Digital
Discrete
06h
Performance Met
or Lags
As & De – Trig Offset M –
Digital Fan 11 5Ah
Fan
04h
Digital
Discrete
06h
Performance Met
or Lags
As & De – Trig Offset M –
LVDS SCSI
channel 1
terminator fault
60h
Terminator
1Ch
Digital
Discrete
06h
Performance Met
or Lags
As – Trig Offset A –
LVDS SCSI
channel 2
terminator fault
61h
Terminator
1Ch
Digital
Discrete
06h
Performance Met
or Lags
As – Trig Offset A –
Power Supply
Status 1
70h
Power Supply
08h
Sensor
Specific
6Fh
Presence
Failure
Predictive Fail
A/C Lost
As & De – Trig Offset A X
Power Supply
Status 2
(SR2400)
71h
Power Supply
08h
Sensor
Specific
6Fh
Presence
Failure
Predictive Fail
A/C Lost
As & De – Trig Offset A X
Power Nozzle
Power Supply 1
78h
Current
03h
Threshold
01h
[u,l][ nr,c,nc] As & De Analog R, T A –
Power Nozzle
Power Supply 2
79h
Current
03h
Threshold
01h
[u,l][ nr,c,nc] As & De Analog R, T A –
Power Gauge
V1 rail (+12v)
Power Supply 1
7Ah
Current
03h
Threshold
01h
[u,l][ nr,c,nc] As & De Analog R, T A –
Power Gauge
V1 rail (+12v)
Power Supply 2
7Bh
Current
03h
Threshold
01h
[u,l][ nr,c,nc] As & De Analog R, T A –
Power Gauge
(aggregate power)
Power Supply 1
7Ch
Other Units
0Bh
Threshold
01h
[u,l][ nr,c,nc] As & De Analog R, T A –
Power Gauge
(aggregate power)
Power Supply 2
7Dh
Other Units
0Bh
Threshold
01h
[u,l][ nr,c,nc] As & De Analog R, T A –
Processor Missing 80h
Module / Board
15h
Digital
Discrete
03h
State Asserted
State Deasserted
As – Trig Offset A –
System ACPI
Power State
82h
System ACPI
Power State
22h
Sensor
Specific
6Fh
S0 / G0
S1
S4
S5 / G2
G3 Mechanical Off
As – Trig Offset A X