Error Code Error Message Response
8130 Processor 01 disabled Warning
8131 Processor 02 disabled Warning
8140 Processor 01 failed FRB-3 timer Warning
8141 Processor 02 failed FRB-3 timer Warning
8150 Processor 01 failed initialization on last boot. Warning
8151 Processor 02 failed initialization on last boot. Warning
8160 Processor 01 unable to apply BIOS update Pause
8161 Processor 02 unable to apply BIOS update Pause
8170 Processor 01 failed BIST Pause
8171 Processor 02 failed BIST Pause
8180 BIOS does not support current stepping for Processor 1 Pause
8181 BIOS does not support current stepping for Processor 2 Pause
8190 Watchdog timer failed on last boot Warning
8198 OS boot watchdog timer failure Pause
8300 BaseBoard Management Controller failed Self Test Pause
8301 Not enough space in Runtime area!!. SMBIOS data will not be available. Pause
8305 Primary Hot swap Controller failed to function Pause
84F1 BIST failed for all available processors Halt
84F2 BaseBoard Management Controller failed to respond Pause
84F3 BaseBoard Management Controller in Update Mode Pause
84F4 Sensor Data Record Empty Pause
84FF System Event Log Full Warning
8500 Bad or missing memory in slot 3A Pause
8501 Bad or missing memory in slot 2A Pause
8502 Bad or missing memory in slot 1A Pause
8504 Bad or missing memory in slot 3B Pause
8505 Bad or missing memory in slot 2B Pause
8506 Bad or missing memory in slot 1B Pause
8600 Primary & Secondary BIOS ID's don't match. Pause
8601 Override Jumper is set to force boot from lower bank of flash ROM. Pause
8602 WatchDog Timer Expired(Secondary BIOS maybe bad!). Pause
8603 Secondary BIOS CheckSum fail. Pause
The following table indicates error codes that are sent to the Management Module for error
logging as a BMC pass-through command. All commands are of “Error” type. The syntax of
error logging with the management module and SEL is different. The same error is logged
differently in the SEL than with the Management Module.
Table 69: Error Codes Sent to the Management Module
Error code Error messages
161 Bad CMOS Battery
301 Keyboard failure
102 System Board failure ( Timer tick 2 test failure)
106 Diskette Controller Failure
604 Diskette Drive ? failure
163 Time of the day not set
01298000 The BIOS does not support the current stepping of Processor P0
01298001 The BIOS does not support the current stepping of Processor P1