Platform Management Intel® Server Board SE7520JR2
Revision 1.0
C78844-002
140
Sensor Name
Sensor
#
Sensor
Type
Event /
Reading
Type
Event Offset
Triggers
Assert /
Deassert
Readable
Value/Offsets
Event Data
PEF
Action
SDR
Record
Type
Tach Fan 6 20h
Fan
04h
Threshold
01h
[u,l][ c,nc] As & De Analog R, T
Fault LED
Action
01
Tach Fan 7 21h
Fan
04h
Threshold
01h
[u,l][ c,nc] As & De Analog R, T
Fault LED
Action
01
Tach Fan 8 22h
Fan
04h
Threshold
01h
[u,l][ c,nc] As & De Analog R, T
Fault LED
Action
01
Tach Fan 9 23h
Fan
04h
Threshold
01h
[u,l][ c,nc] As & De Analog R, T
Fault LED
Action
01
Proc1 IERR 24h
Processor
07h
Sensor
Specific
6Fh
IERR As – Trig Offset – 02
Proc2 IERR 25h
Processor
07h
Sensor
Specific
6Fh
IERR As – Trig Offset – 02
Proc1 Thermal trip 26h
Processor
07h
Sensor
Specific
6Fh
Thermal Trip As – Trig Offset
Fault LED
Action
02
Proc2 Thermal trip 27h
Processor
07h
Sensor
Specific
6Fh
Thermal Trip As – Trig Offset
Fault LED
Action
02
Proc1 Throttle 28h
Temp
01h
Threshold
01h
[u,l][ c,nc] As & De Analog Trig Offset
Fault LED
Action
01
Proc2 Throttle 29h
Temp
01h
Threshold
01h
[u,l][ c,nc] As & De Analog Trig Offset
Fault LED
Action
01
Diagnostic Interrupt
Button
2Ah
Critical
Interrupt
13h
Sensor
Specific
6Fh
FP NMI Button As – Trig Offset NMI Pulse 02
Chassis Identify
Button
2Bh
Button
14h
Generic
03h
Sate
Deasserted
State Assert
As & De – Trig Offset
ID LED
Action
02
Proc1 Fan 2Ch
Fan
04h
Threshold
01h
[u,l][ c,nc] As & De Analog R, T
Fault LED
Action
01
Proc2 Fan 2Dh
Fan
04h
Threshold
01h
[u,l][ c,nc] As & De Analog R, T
Fault LED
Action
01
Proc1 Core temp 2Eh
Temp
01h
Threshold
01h
[u,l][ c,nc] As & De Analog R, T
Fault LED
Action
01
Proc2 Core temp 2Fh
Temp
01h
Threshold
01h
[u,l][ c,nc] As & De Analog R, T
Fault LED
Action
01
CPU Configuration
Error
30h
Processor
07h
Generic
03h
State Asserted As & De Discrete R, T
Fault LED
Action
02
OEM Type 53h -
OEM Type
53h
N/A N/A N/A N/A N/A N/A N/A