Integrator’s Reference Manual
6-36 80-99208-1 Rev. D
Power-On/Reset Default Value(s)
<format> = 3
(for format 3 parity value is ignored)
<parity> = 3 (no parity is actual configuration)
Results Returned
Set Local Flow Control (+IFC)
Syntax
+IFC[=<DCE_by_DTE>|=[<DCE_by_DTE>],
[<DTE_by_DCE>]|?|=?]
Description
Controls the operation of local flow control between the
modem (DCE) and DTE:
•
<DCE_by_DTE> specifies the method of flow control to be
used by the DTE to control the flow of data from the
modem.
•
<DTE_by_DCE> specifies the method of flow control to be
used by the modem to control the flow of data from the
DTE.
Note
This command has no effect on the configuration of the Control port of
the modem’s Rm interface. The Control port’s configuration is fixed with
no flow control.
Result Condition
OK <format> and/or <parity> are
recognized and supported, and have
been processed correctly.
ERROR A parameter value was out of range
or a syntax error was encountered.
+ICF: <format>,
<parity>
OK
? is used to query current setting.
+ICF: (3), (0-3)
OK
=? is used to query acceptable range
of parameters.