Integrator’s Reference Manual
5-26 80-99208-1 Rev. D
3. Use Dial-Up Networking to initiate a packet data call on
the Data port.
For help with Dial-Up Networking, see your Windows
documentation.
4. Start a browser, go to a Web page such as
http://www.globalstar.com, and download something.
5. Wait for the data transfer to end, then wait 10 seconds for
the idle timer to expire.
or
On the Control port, type
ATH777 <CR> to hang up the call
and immediately put the modem into dormant mode.
6. On the Control port, type
AT$QCSTATUS <CR> and observe
how the
CALL STATE is IDLE, indicating that the modem
has entered dormant mode.
7. In your browser connected to the Data port, click another
link.
8. On the Control port, type
AT$QCSTATUS <CR> and observe
how the
CALL STATE is no longer IDLE.
Note
For the above example to work, AT&C0 must be set so that DCD
remains asserted in dormant mode. Otherwise, the networking
application will terminate the PPP session. For more information, see
DCE Received Line Signal Detector Behavior (&C) on page 6-16. For
more information about dormant mode, see Set Dormant Mode Timeout
Value (+CTA) on page 6-49.