Integrator’s Reference Manual
vi 80-99208-1 Rev. D
DCE Received Line Signal Detector Behavior (&C) .............6-16
DTE Data Terminal Ready Behavior (&D) ...........................6-16
Set to Factory-Defined Configuration (&F) ...........................6-17
Basic Action Commands .......................................................................... 6-18
Answer Incoming Call (A) ......................................................6-18
Repeat Last Command (A/) ....................................................6-19
Dial (D) ....................................................................................6-20
Hook Control (H) ....................................................................6-22
Return to Online Data Mode (O) ...........................................6-23
Basic S-Registers...................................................................................... 6-24
Results Returned ....................................................................6-24
Automatic Answer (S0) ...........................................................6-25
Command Line Termination Character (S3) ........................6-25
Response Formatting Character (S4) ....................................6-26
Command Line Editing Character (S5) .................................6-27
Pause Before Blind Dialing Time (S6) ...................................6-27
Connection Completion Timeout (S7) ....................................6-28
Comma Dial Modifier Time (S8) ............................................6-29
Carrier Detect Threshold Timeout (S9) .................................6-29
Carrier Loss to Disconnect Timeout (S10) ............................6-30
DTMF Tone Duration and Spacing (S11) ..............................6-31
Globalstar-Specific S-Register Extensions.............................................. 6-31
Silent Retry Timeout (S777) ..................................................6-31
Extended Configuration AT Commands ................................................. 6-32
Set Forward MUX Option (+CMUX) .....................................6-32
Set Rm Interface Protocol (+CRM) ........................................6-33
Get Modem User Terminal ESN (+GSN) ..............................6-34
Set Character Framing (+ICF) ..............................................6-35
Set Local Flow Control (+IFC) ...............................................6-36
Set Rm Interface Command Baud Rate (+IPR) ....................6-38
Online-Command Mode Commands........................................................ 6-40
Change from Online to Online-Command Mode (+++) .........6-40
Asynchronous Data through Gateway IWF Commands ........................ 6-41
Set Remote Config String (+CFG) .........................................6-41
Data Compression Control Command (+DS) ........................6-42
Error Control Selection Command (+ES) ..............................6-45
Modulation Selection Command (+MS) .................................6-47