Table 3-1. Service Programming Parameters You Must Set
Parameter /
Default
Description Action Required
for the Modem to Operate
Globalstar IMSI
(Mobile Country
Code component)
Factory default:
Unprogrammed
The 3-digit Mobile Country Code
(MCC) component of the
Globalstar International Mobile
Subscriber Identity (IMSI). The
MCC component of the IMSI is
generally the same as the Home
Service Provider MCC (but could
be different based on the
activating SP’s requirements).
Re-program this parameter from
the factory default setting to a
valid MCC, in accordance with
the activating SP’s instructions.
Where in UTPST:
Globalstar NAM dialog
Globalstar IMSI
(Mobile Network
Code component)
Factory default:
Unprogrammed
The 1- to 3- digit Mobile Network
Code (MNC) component of the
Globalstar IMSI. The MNC
component of the IMSI is
generally the same as the Home
Service Provider MNC (but could
be different based on the
activating SP’s requirements).
Re-program this parameter from
the factory default setting to a
valid MCC in accordance with
the activating SP’s instructions.
Where in UTPST:
Globalstar NAM dialog
Globalstar IMSI
(Mobile Station
Identification
Number (MSIN)
Factory default:
Unprogrammed
The mobile station identification
number (MSIN) component of the
Globalstar IMSI.
Re-program this parameter from
the factory default setting to a
valid MSIN in accordance with
the activating SP’s instructions.
Where in UTPST:
Globalstar NAM dialog
Globalstar Home
Gateway Channel
Factory default:
Unprogrammed
The home gateway channel on
which the modem should look for
service. Can be a value from 1
through 124.
Re-program this parameter from
the factory default setting to a
valid Home Gateway channel in
accordance with the activating
SP’s instructions.
Where in UTPST:
Globalstar NAM dialog
Globalstar Home
Gateway ID
Factory default:
Unprogrammed
A numerical identifier
representing the Globalstar Home
Gateway.
Re-program this parameter from
the factory default setting to a
valid Home Gateway ID in
accordance with the activating
SP’s instructions.
Where in UTPST:
Globalstar NAM dialog