Symbol Technologies WS 2000 Switch User Manual


 
WS 2000 Wireless Switch System Reference Guide10-222
WS2000>admin(system.redundancy)> set
Description:
Sets the parameters for redundant switch mode.
Syntax:
Example:
admin(system.redundancy)>set mode standby
can not set the value when the op_state is either upgrade or standalone
admin(system.redundancy)>set op-state redundancy
admin(system.redundancy)>set mode standby
admin(system.redundancy)>
Related Commands:
set mode primary /
standby
Tells the switch that it is either the primary or secondary (standby) switch when redun-
dancy is enabled. This parameter can only be set if the op-state parameter is set to
redundancy.
op-state upgrade /
standalone /
redundancy
Sets the redundancy operation state of the switch to one of:
standalone—The switch has no redundancy capabilities and operates independently
of any other WS 2000 switches on the network. This is the default setting.
redundancy—Two WS 2000 switches are connected, with one set as a primary and
the other as a standby.
upgrade—The primary and standby switches must run the same version of the switch
firmware for redundancy to work correctly. If the firmware on only one of the switches
is updated, redundancy is disabled and the Operational State is automatically set to
Upgrade.
heartbeat
<interval>
Sets the heartbeat interval for the switch to <interval> (160) seconds.
revertdelay
<delay>
Specifies the amount of time (120 minutes) after not receiving a heartbeat packet before
the secondary (standby) switch will take over.
hb_interface
<port>
Indicates which port on the switch (16) is the heart beat port. This is the port that con-
tains the Ethernet cable that attaches the two switches.
show Displays the redundancy settings.