3Com 5500 Switch User Manual


 
Configuring BPDU Tunnel 325
Configure the service provider network to transmit NDP packets of the
customer network through a BPDU tunnel.
Enable VLAN-VPN for the service provider network, and enable the service
provider network to use VLAN 100 to transmit data packets of the customer
network.
Applicable Products
Configuration Procedure
Configure Provide 1.
# Disable NDP on Ethernet 1/0/1.
<3Com> system-view
[3Com] interface Ethernet 1/0/1
[3Com-Ethernet1/0/1] undo ndp enable
# Enable the BPDU tunnel feature for NDP BPDUs on Ethernet 1/0/1.
[3Com-Ethernet1/0/1] bpdu-tunnel ndp
# Enable the VLAN-VPN feature on Ethernet 1/0/1 and use VLAN 100 to tunnel
user data packets.
[3Com-Ethernet1/0/1] port access vlan 100
[3Com-Ethernet1/0/1] vlan-vpn enable
# Configure Ethernet 1/0/2 as a trunk port that permits packets of VLAN 100.
[3Com] interface Ethernet 1/0/2
[3Com-Ethernet1/0/2] port link-type trunk
[3Com-Ethernet1/0/2] port trunk permit vlan 100
Configure Provide 2
# Disable NDP on Ethernet 1/0/4.
<3Com> system-view
[3Com] interface Ethernet 1/0/4
[3Com-Ethernet1/0/4] undo ndp enable
# Enable BPDU tunnel for NDP BPDUs on Ethernet 1/0/4.
[3Com-Ethernet1/0/4] bpdu-tunnel ndp
# Enable the VLAN-VPN feature on Ethernet 1/0/4 and use VLAN 100 to tunnel
user data packets.
[3Com-Ethernet1/0/4] port access vlan 100
[3Com-Ethernet1/0/4] vlan-vpn enable
# Configure Ethernet 1/0/3 as a trunk port that permits packets of VLAN 100.
Product series Software version Hardware version
Switch 5500 Release V03.02.04 All versions
Switch 5500G Release V03.02.04 All versions
Switch 4500 Release V03.03.00 All versions