11. Configurator, Communication settings
5. Click Apply to activate (c).
Image 11-2
Network settings, manually
The PC’s IP Address MUST be within the same subnet as the projector’s IP Address in
order for communication to be possible. This requires checking the PC’s and projector’s
Subnet-Mask settings.
IP address examples
First example
PC IP Address : 192.168.100.5
PC Subnet Mask : 255.255.255.0
Projector IP Address : 192.168.100.3
Projector Subnet Mask: 255.255.255.0
Result : Communication possible. PC address is in the subnet range of the projector’s IP address.
Second example
PC IP Address : 10.16.236.100
PC Subnet Mask : 255.255.255.0
Projector IP Address : 192.168.100.3
Projector Subnet Mask: 255.255.255.0
Result : No communication possible. PC address is not in the subnet range of the projector’s IP address.
Third example
PC IP Address : 192.168.200.1
PC Subnet Mask : 255.255.255.0
Projector IP Address : 192.168.100.3
Projector Subnet Mask: 255.255.255.0
Result : No communication possible. PC address is not in the subnet range of the projector’s IP address.
The third group in the PC IP address and Projector IP address must be the same.