6. Configurator, General projector settings
Image 6-11
Input locking, free run options
Manual lock can be switched On or Off just by checking the check box next to Manual lock.
Manual
lock on :
locking is done on the indicated vertical frequency which can be changed by the user.
Manual
lock off :
locking is done on an internal sync (60 Hz).
To change the locking frequency for manual lock on, click on the up down control next to Vert freq until
the desired value is reached or
click in the input field, select the current value and enter a new value with the keyboard.
Options for Automatic or specific input
When Automatic or specific input is selected, the Genlock input settings become available.
Image 6-12
Input locking, automatic or specific input options
Genlock can be switched On or Off just by checking the check box next to Genlock.
Genlock
off
(default position) locking done on input source of main window, when automatic was
selected or on the selected input source when a specific input was selected. Projector
detects automatically the vertical frequency and clock frequency of the input signal. A
slightly difference with the source is possible.
Genlock
on
locking done on indicated vertical frequency and clock frequency. This vertical frequency
and clock frequency must be exactly the same as those of the source.
Only use genlock ON for very stable sources and preferable for broadcast sources.
For Genlock on,
To change the Clock frequency, click on the up down control next to Clock freq until the desired value is
reached or
click in the input field, select the current value and enter a new value with the keyboard.
To change the Vertical frequency, click on the up down control next to Vert freq until the desired value is
reached or
click in the input field, select the current value and enter a new value with the keyboard.
R5976924 PROJECTOR TOOLSET 16/04/2009
79