header (sticky submode)
header (sticky submode)
To stick a connection based on the contents of the HTTP header, use the header command in the sticky
configuration submode.
header offset value length value
Syntax Description
Defaults The default offset value is 0.
The default length value is 4400.
Command Modes Sticky configuration submode
Command History
Examples This example shows how to configure the header offset and length:
Cat6k-2(config-slb-sticky-header)# header offset 5 length 500
Related Commands sticky
show module csm sticky
offset value Specifies the number of bytes to ignore from the start of the header.
Valid values are from 0 to 3399.
length value Specifies the number of bytes to parse in the header. Valid values are
from 1 to 4000.
Release Modification