interval (probe submode)
interval (probe submode)
To set the time interval between probes, use the interval command in the SLB probe configuration
submode. To reset the time interval between probes to default, use the no form of this command.
interval seconds
no interval
Syntax Description
Defaults The default value for the interval between probes is 120 seconds.
Command Modes SLB probe configuration submode
Command History
Usage Guidelines This command is used for all probe types.
Examples This example shows how to configure a probe interval of 150 seconds:
Cat6k-2(config-slb-probe-http)# interval 150
Related Commands probe
show module csm probe
seconds Number of seconds to wait between probes from the end of the
previous probe to the beginning of the next probe; the range is from
2 to 65535.
Release Modification
CSM release 1.1(1) This command was introduced.