Gateway 9715 Server User Manual


 
135
www.gateway.com
Power subsystem
To replace a power supply module or active fan blank:
1 Examine the LED indicators on the back of each power supply modules to identify
the failed module. The power supply module has failed if the center Fault LED (orange)
indicator is on. If your server has two power supply modules, go to Step 3.
2 Turn off the server.
3 Unplug the power cord from the failed power supply module.
4 Push down the thumb tab to unlock the power supply module (or active fan blank)
handle, then pull down the handle to disengage the module (or active fan blank) from
the chassis and pull the module (or active fan blank) straight out from the server.
5 Place the power supply module (or active fan blank) on a clean, ESD-protected surface.
6 With the handle in the open position, slide the new power supply module (or active
fan blank) into the power supply module bay until it stops.
7 Push the handle up against the power supply module (or active fan blank) until the
thumb tab clicks into place.
8510702.book Page 135 Thursday, July 7, 2005 11:21 AM