Baseboard Management Controller (BMC)
Baseboard Management Controller (BMC)
The Baseboard Management Controller (BMC) monitors system platform management
events and logs their occurrences in the non-volatile System Event Log (SEL). This includes
events such as over temperature and over-voltage conditions, and fan failures. The BMC
can also provide the interface to the monitored information so system management
software can poll and retrieve the present status of the platform.
The BMC also provides the interface to the non-volatile Sensor Data Record (SDR)
repository. Sensor Data Records provide a set of information that system management
software can use to automatically configure itself for the number and type of IPMI sensors
(such as temperature and voltage sensors) in the system.
The following is a list of the major functions of the BMC:
System power control (including providing Sleep/Wake push-button interfaces for
ACPI
Platform Event Paging (PEP) / Platform Event Filtering (PEF)
Monitoring:
Power Distribution Board monitoring
Temperature and voltage monitoring
Fan failure monitoring
Processor presence monitoring (no processors installed) and processor temperature
monitoring
Interlock monitoring
Processor core ratio speed setting
Speaker beep capability on standby and when system is powered up
Hot-plug PCI slot status reporting
Chassis control:
General fault light control
Chassis cooling failure light control
Chassis power fault light control
Chassis power light control
Chassis ID LEDs control
System Event Log (SEL) interface
Sensor Data Record (SDR) repository interface
8510702.book Page 45 Thursday, July 7, 2005 11:21 AM