Baseboard Management Controller (BMC)
4 Move the shorting block from pins 2-3 to pins 1-2 on the Boot Block Update jumper
(J1B1) on the IMM module.
5 Follow the instructions in “Closing the server case” on page 72, then reconnect the
power cord.
6 Download the current SUP CD image from www.support.gateway.com and create a
DOS-bootable SUP CD. For information on creating a SUP CD, see “Creating a
DOS-bootable System Update Package (SUP) CD” on page 42.
7 Follow the instructions in “Booting from the SUP CD:” on page 43.
8 Follow the instructions on the menu to update the firmware.
9 Turn off the server, then disconnect the power cord and wait for the Standby power
LED to turn off.
10 Follow the instructions in “Opening the server case” on page 66.
11 Replace the processor air baffle by following the instructions in “Removing and
installing the processor air baffle” on page 67.
Important
At the completion of the firmware update, an error message 009 will
be displayed. This error message can be ignored.
1 2 3
3
2
2 - 3 Default - Boot block
protected
1 2 3
2
1
1 - 2 Boot block unprotected
J1B1