40672201TX Rev.4
4 - 87
Fig. 4-3-13-1/3 Counter Display/Clear (In case of Service bit = OFF&TOWER COUNT CLEAR=ON)
14:14 FAX
SELECT FUNCTION (OT)
MEMORY AVAIL.= 100%
→ key
← key
← key
← key
Press FUNCTION key.
DRUM COUNT
CLEAR(←) NEXT(→)
ARE YOU SURE ?
CLEAR(←) NEXT(→)
PRINT COUNT XXXXXX
NEXT(→)
SCAN COUNT XXXXXX
NEXT(→)
CLEAR
Press OT7 key.
→ key
→ key
TONER COUNT
CLEAR(←) NEXT(→)
→ key
→ key
No. of counter (pages) will not appear for user.
No. of print counter and scan counter (pages)
will appear but cannot be cleared by user.
Clear Operation: User can clear only DRUM counter.
When the drum has reached its life span, LCD shows REPLACE I/D
UNIT. After having cleared the drum counter, warning message will be
disappeared.
End of programming + 1 second
(Flash memory writing)
Drum reaches
its lite span.