Oki FX-051 Fax Machine User Manual


 
40672201TX Rev.4
2 - 7
2.2 General Function Specifications
General function specifications for the product are given below. They are summaries of
whole descriptions. For convenience of description, the functions are classified in two
categories:
User functions and Service functions.
2.2.1 User functions
1) Transmissions
Transmission is available by auto dial (10 one-touch numbers, 70 two-digit numbers,
as well as standard keypad dialing).
2) Reception
Reception is available by auto reception and manual reception.
3) Dual access
The machine can scan another document into document memory during memory TX/
RX and paper reception.
4) Voice request
A voice request from the transmitter is available only upon completion of the total
message transmission.
A voice request from the receiver is available at the end of each page being received.
A voice request function is available in normal transmission and normal reception.
(refer to Table 4-x)
5) Auto redial
If a call cannot be connected to the distant station because the line is busy or no
answer is returned, this feature redials the same station after a predetermined interval.
The redial interval and the number of redial tries are set by the user in the US/
CANADA version and in some INT’L versions where allowed by the PTT, and by a
service engineer in other INT’L versions.
If a communication terminates with an error in memory TX mode (no response to
POST-COMMANDS) the machine re-dials and re-transmits from the first page to the
same station.