8. ENVIRONMENTAL REQUIREMENTS
8.1 Power
8.1.1 AC Voltage Range
The machine will operate within A/B, as shown in Table 8-1. Operation within the ranges
listed will be on a continuous basis.
Table 8-1 Voltage Range
Voltage Nominal Value MinimumValue Maximum Value
Range (Volts) (Volts) (Volts)
A: U.S./CANADA 120 102 127
B: INT’L 230 198 *250
Note: The power supply will actually work at 264 volts, but the maximum value shows
250 volts according to PTT regulation.
8.1.2 Frequency Range
The machine will operate on AC power having a frequency in the range of 49 to 61 Hertz.
8.1.3 Transients
The machine will operate without error under the following conditions:
Dropouts: 10 msec (Period: 1 sec)
Noise: [without error]
500 V (Pulse width:100 ns/800 ns, Rising time: 1 ns)
[without memory loss]
1000 V (Pulse width: 100 ns/800 ns, Rising time: 1 ns)
8.1.4 Power Consumption
The machine will not exceed the maximum values shown in Tables 8-2 and 8-2a.