Sony MKS-2017 Switch User Manual


 
Chapter 9 System Settings
177Other Settings
a) 1.5 M/E panel only
b) When [Snapshot Recall ?] is selected, press [Register No] to set a register
number (1 to 99).
Setting switcher GPI outputs
1
From the top menu, select Setup/Diag >GPI >SWR
GPI Out.
The SWR GPI Output menu appears. The status area
shows the GPI output ports, and the trigger type,
output timing, pulse width, and action set for the signal
to be output from each port.
2
Select the port for which you want to make the setting.
Press directry on the list in the status area.
Use the arrow buttons to scroll the reverse video
cursor.
Turn the knob.
a) Select 1 to 8 for GPI ports (G-1 to G-8), and 9 to 16 for tally ports
(T1 to T8).
To change the trigger type setting
Press [Trigger Type], to display a popup window, and
select the trigger type.
(falling edge): The trigger closes the relay contacts
or causes a low output level, and this state is
maintained for the specified pulse width.
(rising edge): The trigger opens the relay contacts or
causes a high output level, and this state is maintained
for the specified pulse width.
(both edges): Each time the trigger is activated, the
relay switches between open/closed or the output level
switches between high/low.
Status: Depending on the state, the relay is switched open/
closed or the output level is switched high/low.
Disable (disabled): No output.
To change the timing setting
When the trigger type is other than [Status] or [Disable],
press [Timing] to display a popup window, and select the
timing.
Any: Output on the earliest field that can be processed.
Field 1: Output on field 1.
Field 2: Output on field 2.
Note
When the following signal formats are selected, it is not
possible to set the timing.
1080PsF/23.976
1080PsF/24
1080PsF/25
1080PsF/29.97
720p/59.94
To change the pulse width setting
When the trigger type is (falling edge) or
(rising edge), turn the knobs to set the pulse width.
To change the action setting
Press [Action] to display a popup window, and select the
action.
M/E Key1 Cut M/E K1 Cut
M/E Key2 Auto Trans M/E K2 AT
M/E Key2 Cut M/E K2 Cut
DSK1 Auto Trans DSK1 AT
DSK1 Cut DSK1 Cut
DSK2 Auto Trans DSK2 AT
DSK2 Cut DSK2 Cut
FTB Auto Trans FTB AT
FTB Cut FTB Cut
Snapshot Recall ?
b)
Snapshot
No Action No Action
FM V Field Freeze
FM V Field
FM V Frame Freeze
FM V Frame
FM V Freeze Off
FM V Off
FM K Field Freeze
FM K Field
FM K Frame Freeze
FM K Frame
FM K Freeze Off
FM K Off
Action button Status area display
Knob Description Setting
values
1 (Port) GPI output port number
selection
1 to 16
a)
Knob Description Setting values
2 (Pulse Width) Pulse width 1 to 60 (fields)
Action button Status area display
M/E Auto Trans M/E AT
M/E Cut M/E Cut
P/P Auto Trans
a)
P/P AT