186 Other Settings
Chapter 9 System Settings
To delete parallel tally settings
In step 2, select a tally port and press [Clear].
Making wiring settings
When configuring a system in which the switcher inputs
and outputs are connected to a router, it is necessary to set
up this connection configuration (referred to as “wiring”)
in the S-Bus space.
To make new wiring settings
1
From the top menu, select Setup/Diag >System Tally
Wiring.
The Wiring menu appears. The status areas shows
wiring information.
2
Press [New], turning it on, and turn the knobs to set the
following parameters.
3
Press [Set].
To modify wiring settings
1
If [New] is on, turn it off.
2
Using any of the following methods, select the wiring
setting to modify.
• Press directry on the list in the status area.
• Use the arrow buttons to scroll the reverse video
cursor.
• Turn the knob.
3
Turn the knobs to set the following parameters.
4
Press [Set].
To sort wiring settings
1
Select a wiring setting by carrying out steps 1 and 2 of
“To modify wiring settings,” then press [Sort].
A popup window appears.
2
Execute the sort by selecting one of the following sort
orders.
Dest: Destination level/address
The wiring settings are sorted as follows.
Ascending order (smallest first) by destination
level t ascending order by destination address
t ascending order by source level t ascending
order by source address.
Source: Source level/address
The wiring settings are sorted as follows.
Ascending order (smallest first) by source level
t ascending order by source address t
Ascending order by destination level t
ascending order by destination address.
To delete wiring settings
Select a wiring setting by carrying out steps 1 and 2 of “To
modify wiring settings,” then press [Delete].
Copying tallies
You can copy tally source information to another tally
source.
To make new tally copy settings
1
From the top menu, select Setup/Diag >System Tally
>Tally Copy.
The Tally Copy menu appears. The status area shows
the current tally copy settings.
Knob Description Setting values
1 (Dest From) Destination start
address
1 to 1024
2 (Dest To) Destination end
address
1 to 1024
3 (Dest Lvl) Destination level 1 to 8
4 (Src From) Source start address 1 to 1024
5 (Src Lvl) Source level 1 to 8
Knob Description Setting values
1 (No) Wiring number selection 1 and upwards
Knob Description Setting values
2 (Dest Add) Destination address 1 to 1024
3 (Dest Lvl) Destination level 1 to 8
4 (Src Add) Source address 1 to 1024
5 (Src Lvl) Source level 1 to 8