Chapter 9 System Settings
183Other Settings
2
Press [Matrix Size].
A popup window appears.
3
Select the matrix size.
Standard 136 × 138: Assign the switcher S-Bus space
at full size. You can assign all switcher inputs and
outputs to the S-Bus space, but this causes some
waste of S-Bus space.
Compact 128 × 128: Assign the switcher S-Bus space
at compact size. It is not possible to assign all
switcher inputs and outputs to the S-Bus space, but
the S-Bus space can be used efficiently.
4
Press [S-Bus Assign].
5
Turn the knobs to set the following parameters.
a) When matrix size is Standard 136 × 138
b) When matrix size is Compact 128 × 128
Making external box settings
If you need to acquire the signal selection status of external
devices via parallel input, assign a matrix to S-Bus space
as an external selector (external box).
1
From the top menu, select Setup/Diag >System Tally
>External Box.
The External Box menu appears. The status area
shows a list of device names, matrix sizes, source
addresses, destination addresses, and levels. “No
Assign” appears in the [Matrix Size] column of unused
external boxes.
Note
The switcher (SWR) is displayed, but cannot be set
here. To make switcher settings, use the S-Bus Assign
menu.
2
Using any of the following methods, select the
external box to set.
• Press directry on the list in the status area.
• Use the arrow buttons to scroll the reverse video
cursor.
• Turn the knob.
3
Press [Matrix Size].
A popup window appears.
4
Select the matrix size
No Assign: Do not use.
8 × 1: Select an external box with 8 inputs and 1
output.
16 × 1: Select an external box with 16 inputs and 1
output.
32 × 1: Select an external box with 32 inputs and 1
output.
5
Press [S-Bus Assign].
6
Turn the knobs to set the following parameters.
a) When matrix size is 8 × 1
b) When matrix size is 16 × 1
c) When matrix size is 32 × 1
Knob Description Setting values
1 (Source) Source start address
1 to 889
a)
1 to 897
b)
2 (Destination) Destination start
address
1 to 887
a)
1 to 897
b)
3 (Level) Level in S-Bus space 1 to 8
Knob Description Setting values
1 (Ext Box No) External box selection 1 to 4
Knob Description Setting values
2 (Source) Source start address
1 to 1017
a)
1 to 1009
b)
1 to 993
c)
3 (Destination) Destination start
address
1 to 1024
4 (Level) Level in S-Bus space 1 to 8