Chapter 9 System Settings
179Other Settings
a) 1.5 M/E panel only
b) When [Snapshot Recall ?] is selected, press [Register No] to set a register
number (1 to 99).
Setting the action when the trigger type is [Level]
When the trigger type is [Level], press [Action] to display
a popup window, then you can select the following four
actions.
When other than [No Action] is selected, you can set the
action separately for when the input is high level and when
the input is low level. To set the action when the input is
high level, press [High Level], and to set the action when
the input is low level, press [Low Level], to display a
popup window.
When [Signal Format] is selected: In the popup window,
press any of the following action buttons, to select the
action when the input goes to the high level/low level.
•576i/50
•480i/59.94
• 720P/59.94
• 1080i/50
• 1080i/59.94
• 1080PsF/23.976
• 1080PsF/24
• 1080PsF/25
• 1080PsF/29.97
•No Action
When [Screen Aspect] is selected: In the popup window,
press the following action buttons, to select the action
when the input goes to the high level/low level.
•4:3
•16:9
•No Action
When [Level Enable] is selected: In the popup window,
press the following buttons, to select the action when
the input goes to the high level/low level.
• Enable
•Disable
•No Action
Note
When using [Signal Format] and [Screen Aspect], set the
[Level Enable] GPI input to [Enable]. If this is not set to
[Enable], the GPI inputs are not valid.
GPI outputs of the control panel
The GPI outputs of the control panel are fixed as follows,
so you need not make settings for them.
Assigning GPI inputs to DCU parallel input
ports
You can assign GPI inputs to DCU parallel input ports
which are not being used for tally external box input and
tally enable input.
See “Tally Setup (System Tally Menu)” (page 182) for
more information about tally external box input and tally
enable input.
1
From the top menu, select Setup/Diag >GPI >DCU In
Config.
The DCU Input Config menu appears.
P/P Auto Trans
a)
P/P AT
P/P Cut
a)
P/P Cut
M/E Key1 Auto Trans M/E K1 AT
M/E Key1 Cut M/E K1 Cut
M/E Key2 Auto Trans M/E K2 AT
M/E Key2 Cut M/E K2 Cut
DSK1 Auto Trans DSK1 AT
DSK1 Cut DSK1 Cut
DSK2 Auto Trans DSK2 AT
DSK2 Cut DSK2 Cut
FTB Auto Trans FTB AT
FTB Cut FTB Cut
Snapshot Recall ?
b)
SnapShot
No Action No Action
FM V Field Freeze
FM V Field
FM V Frame Freeze
FM V Frame
FM V Freeze Off
FM V Off
FM K Field Freeze
FM K Field
FM K Frame Freeze
FM K Frame
FM K Freeze Off
FM K Off
Macro Take
Macro
Action button Status area display
No Action No Action
Signal Format Format
Screen Aspect Aspect
Level Enable Enable
Action button Status area display
Port number Action
GPI-1 Error Status
GPI-2 No Action
GPI-3 No Action
GPI-4 No Action
GPI-5 M/E Key1 On Status
GPI-6 M/E Key2 On Status
GPI-7 DSK1 On Status
GPI-8 DSK2 On Status