3Com V7000 Network Router User Manual


 
Adding UPS Support to an Existing VCX System 127
Requirements Setting up a VCX system to use UPS power and to monitor UPS status
using the
vcx-ups-setup command requires the following configuration
information for each UPS in the VCX system:
IP address of the UPS — You must know the pre-configured IP address
assigned to the UPS.
SNMP community string — You must know the pre-configured SNMP
write community string assigned to the UPS.
Low battery threshold percentage — You must specify the battery
charge level (expressed as a percentage of battery capacity) at which
point the attached server (or servers) should initiate a shutdown.
You must also supply the following information for each VCX server:
Whether a server is the master or a slave
On each slave server, the IP address of the master VCX server
Adding Single UPS
Device Support
This section describes how to configure a VCX system supported by a
single UPS. Depending on your VCX configuration, this requires one or
two general steps:
If your VCX system includes a single VCX server, configure that system
as the master.
If your VCX system includes multiple VCX servers, configure one server
as the master and the remaining servers as slaves.
Single UPS System – Configuring the Master VCX Server
To initially enable and configure a VCX server as the master in a single
UPS system:
1 Log in, using the root account, to the VCX server you want to designate
as the master.
2 Enter the following command:
vcx-ups-setup <configuration_parameters>
You must concatenate the following vcx-ups-setup command
configuration parameters (responses are shown in bold):
-- master: Y
Enter Y (you must uppercase) to designate this server as the master.
-- monitormultipleups: N