3Com V7000 Network Router User Manual


 
206 APPENDIX A: UPGRADING VCX SERVER SOFTWARE FROM V7.0 TO V7.1
cd /opt/installtemp
tar xvf vcx-bss-7.1.xc.tar
cd upgrade-7.1.xc
./install-upgrade
The system may prompt you to confirm that a new operating system
version will be installed and indicates which disk partition will be used
after the upgrade. If you see such a prompt, answer y.
The system displays several status messages. The last two messages are:
------------------- Installation Completed Successfully -------------------
------------------- VCX version 7.1.xc is now available -------------------
4 Change to the new software version by entering this command:
vcx-switchversion 7.1.xc
The system displays several status messages and provides prompts that
allow you enable UPS Monitoring.
5 The UPS Monitoring prompt appears:
An Uninterruptible Power Supply (UPS) can be used with VCX
systems to avoid disruption due to a power outage. VCX
provides a UPS monitoring service which tracks the UPS's
status and performs a safe shutdown when the its battery is
depleted during a long power outage. To use this feature,
you must have a compatible UPS installed and configured in
accordance with the VCX documentation.
Enable UPS monitoring? [N] :
If you do not have a UPS installed and enter n (or press Enter); the
remaining UPS configuration prompts are not displayed.
If you do have a UPS installed and enter
y and see Configuring UPS
Monitoring for information on the subsequent UPS configuration
prompts.
6 After completing the UPS Monitoring prompts, the server reboots. When
the reboot process has been completed, the system starts VCX 7.1.x
services.
After the system has completed the restart process, verify that the
upgrade has occurred by entering the following command:
ls -l /opt/3com/VCX
The symbolic link (VCX) should point to the new version of the VCX
software (7.1.xc). If the link does not point to the new version, wait a few