3Com V7000 Network Router User Manual


 
Upgrading a Multi-Site VCX System with Branch Offices 213
UPS Monitoring requires a network-enabled UPS. Enter the IP
address assigned to the UPS's management card or Ethernet
interface. Note: The UPS must already be configured with
this address.
UPS IP address :
Enter the IP address assigned to the UPS.
4 The upgrade script prompts you for the SNMP write community string
assigned to the UPS:
The SNMP 'write' community string configured in the UPS is
required. (For security reasons, it is recommended that the
default value provided by the UPS be changed.)
UPS 'write' community string :
The string you enter here must match the SNMP write community string
configured on the UPS.
5 If you answered yes in step 1 (indicating multiple UPS devices), the
upgrade script prompts you for the IP address of the second UPS:
Enter the IP address assigned to the second UPS's management
card or Ethernet interface. Note: The UPS must already be
configured with this address.
Second UPS IP address :
6 The upgrade script prompts you for the SNMP write community string
assigned to the second UPS:
The SNMP 'write' community string configured in the second
UPS is required.
Second UPS 'write' community string :
The string you enter here must match the SNMP write community string
configured on the UPS.
7 The upgrade script prompts you for the battery charge level (expressed as
a percentage of battery capacity) at which point the attached server (or
servers) should initiate a shutdown:
A 'low battery' condition is reached when the battery charge
reaches a defined threshold percentage.
Low Battery Threshold (%) : 25