3Com V7000 Network Router User Manual


 
188 APPENDIX A: UPGRADING VCX SERVER SOFTWARE FROM V7.0 TO V7.1
b The Enter the Number of MASTER SITEs other than the MASTER
DEFINITION SITE
[1]: prompt appears.
Press Enter to accept the default.
c The
Enter the MASTER DEFINITION SITE IP Address [IP
address]
prompt appears.
Enter the IP address of the Master Definition site or press Enter if the
displayed address is correct. This is typically the IP address of eth0 on
the primary VCX server.
d The
Enter the MASTER SITE 1 IP Address [0.0.0.0] prompt
appears.
Enter the IP address of the Master Site. This is typically the IP address
of eth0 on the secondary VCX server.
e The
Do you want to continue with the above settings? [n/y]:
prompt appears.
Enter
y to continue. The script executes.
During script execution, messages appear describing the replication
setup. Messages also appear stating that firewall setup should allow
communication between the primary IP Telephony server and the
secondary IP Telephony server. These messages are a
reminder—firewall setup was performed during VCX software
installation.
f The
Have you executed the ABOVE mentioned VCX-FIREWALL
steps? [y/n]:
prompt appears.
Enter
y to continue. The script executes.
When the replication is complete, Multi-Master Replication Status is
reported as NORMAL. Do not continue to the next step until the
replication is complete. Note that replication can take approximately
20 minutes to complete.
g You can check the replication by entering the following command:
./checkReplication
3 When the replication is complete, enter the following command to exit
the cworks account and return to the root account:
exit