Ericsson LBI-39224 Personal Computer User Manual


 
LBI-39224
3-117
console originated calls. This field is used only for C3
Modular/Desktop consoles.
Caller Label Delay
Time delay, in seconds, that the CALLER is displayed after the call has
dropped. This delay allows the dispatcher to see who made the call for
a short time after the call was dropped. There is a built-in two (2)
second delay for C3 Modular/Desktop consoles which will be added to
any value (0 - 5) selected from the drop-down list box.
Confirm Group Call
Select this check box to enable confirmed call on group and digital
PTTs. Unselect to disable this function.
Maximum Confirm Call Delay
This is the maximum time in seconds that a confirmed PTT will hold
for confirmation from all called sites. All called sites must confirm a
working channel has been assigned before the timer expires; if not, the
console operator will be given a grant tone when the timer expires,
signaling the transmission may proceed in a non-confirmed state. The
valid time delay range is 0 - 10 seconds, select desired value from the
drop-down list box.
Audio Indicators
Mute Volume
This is the volume used at a muted console module when an incoming
call is received. Some dispatchers may want zero volume when they
mute a module and others may want just a lower volume than the
previous volume. Select the desired volume setting (0 - 32) from the
drop-down list box.
Mute All Delay
The time, in seconds, the modules are muted after the MUTE ALL
button is pressed. After the delay expires, volumes will return to
original levels. Select the desired value (0 - 120) from the drop-down
list box.
Default Unselect Speaker
This is the unselect speaker number for unprogrammed or non-
monitored incoming calls. Valid options are speakers 2 through 4,
speaker 1 is for select calls. Select the desired speaker from the drop-
down list box.