Ericsson LBI-39224 Personal Computer User Manual


 
LBI-39224
A-5
LOGGED
ERROR
MESSAGE
LOGGED
ERROR
DATA
CAUSE/
CORRECTIVE
ACTION
E05-021:
INCOMPATIBLE -
AUDIO BUS
E05-023:
INCOMPATIBLE -
CEC/IMC MANAGER
E06-116:
INVALID VALUE -
ASSIGNMENT
No information
contained in the data
word.
A Controller Board was installed
that conflicted with an existing
Controller Board. For example a
MIM 6 and a VMIM 6, or two CIM
1s.
Corrective Action:
Both
interface modules that are
conflicting will have this error
active. Change the device
type/assignment setting of the
board in error. All boards that
conflicted must be reset to clear the
error.
E07-119:
INVALID
REDUNDANCY -
MULTIPLE END
NODES
Lower byte of the
data word contains
the node ID of the
existing end node.
Upper byte of the data
word is reserved.
This Controller Board is set up to
be an end node, but an end node
already exists in the system. This
message replaces warning W06-
119 beginning with MOM
Controller Board firmware version
3.00.
Corrective Action:
To clear
the error, only one (1) Controller
Board should have its end node
DIP switch set to the ON position.