Ericsson LBI-39224 Personal Computer User Manual


 
LBI-39224
3-48
LBI-38938, CEC/IMC Digital Audio Switch Installation, Set-up, and
Troubleshooting.
NIM "Site" Selection
Prior to actual channel configuration, the interface module to be
configured must be selected. From the CEC/IMC Manager menu bar
select Configure System / CEC/IMC Configuration / NIM to display
the Site Channel Configuration List dialog box for that module.
Figure 20 NIM Site Channel Configuration List Dialog Box
Each Site Channel Configuration List dialog box displays the
configurable NIMs and configured/active NIMs. A configured and
active NIM represents an active operating control link between the NIM
Controller Boards in two networked CEC/IMC switches.
Help
Choose the
Help
command button to access the Help function. (Help is
also available by pressing the F1 key.)
Configurable Sites:
The Configurable Sites list box displays all inactive unconfigured site-
type interface modules. If a NIM appears in this box, no channel
configuration exists at the CEC/IMC Manager and no active Controller
Board control data link exists at the CEC/IMC for the corresponding
site assignment number, and the NIM may be selected for
configuration. Any number of these available NIMs may be selected at
one time to be added to the Configured/Active list box for
configuration.