5-1
5. CHAPTER 5
OFF-LINE DIAGNOSTICS
5.1 OFF-LINE DIAGNOSTIC FUNCTIONS
The CEC/IMC Manager (MOM PC) has two off-line MS-DOS
®
utilities to extract data from the data log buffer stored on the hard disk.
CALLS.EXE Used to extract all calls made within the
CEC/IMC
GSCMON.EXE Used to extract all messages from the log
It is recommended that the data log files be backed up to a
floppy disk weekly and removed from the hard disk. This
eliminates the hard disk from filling up and disabling data
logging.
Open an MS-DOS window. From the Windows Program Manager
window double-click on the "Main" icon, then double-click on the
"MS-DOS Command Prompt" icon.
At the DOS prompt type: c:\winmom\calls.exe to execute the
CALL.EXE utility, or c:\winmom\gscmon.exe to execute the
GSCMON.EXE utility. (If the CEC/IMC Manager is installed on a
drive other than C drive, substitute that drive designation for "c" in the
above commands.)
5.1.1 CALLS.EXE
The CALLS function is used to extract channel assignment/drop
messages from the data log buffer. It can be a vital tool in tracing calls
through the system.
The user may obtain help for the CALLS function by using the "/h"
option on the command line. For example: calls /h
The following help message will be displayed: