LBI-39224
3-176
The Selected Module text box displays the module number selected in
the Logging Recorder Configuration dialog box, this is read-only
information.
Select the database (unit, group, or conventional) for the entity you
wish to program by selecting the appropriate option button at the top of
the dialog box. This will automatically program the
LRIM Module Edit dialog box with all entities belonging to that
database. The desired entity for programming is selected from the
drop-down list box which will be labeled according to which database
was selected (Unit ID, Group ID, or Conv ID). Units, groups, and
conventional channels are all programmed in the same manner.
The LRIM also handles the patch/simulselect feature of the
CEC/IMC. If multiple groups are patched/simulselected
together then audio transmissions on the SAID (System
Assigned ID) will be routed to each of those groups
programmed at the LRIM.
The Channel text box will automatically display the channel
corresponding to the selected module in the
Logging Recorder Configuration dialog box. This value may be
edited with any available channel. Summation may be obtained by
assigning multiple modules to the same channel. By assigning each
module a unique channel number, summation will not occur.
Volume levels are adjusted using the Output Level drop-down list box
and selecting the desired volume. The volume range is -25 dBm as the
minimum and +10 dBm as the maximum.
The Programmed text box shows the program status at the Logging
Recorder. This text box is read-only information. A "Yes" indicates
the module is programmed, a module is programmed in the
Logging Recorder Configuration dialog box in one of two ways:
– selecting individual modules in the
Logging Recorder Configuration dialog box and choosing
the Send Mod button (changed data must be saved to disk
prior to programming), or
NOTE