LBI-39224
B-7
LOGGED
WARNING
MESSAGE
LOGGED
WARNING
DATA
CAUSE/
CORRECTIVE
ACTION
"CIC Denied"
warning and the caller
and callee of the
failed confirmed call.
The encrypted Jessica/CTIS call
was denied at the landline
interface.
"CTIM Duplex"
warning and the caller
and callee of the
failed confirmed call.
A "call back" was not received
from the landline interface for
the encrypted Jessica/CTIS call.
This "call back" is required for
the full duplex operation as well
as ringing tone connections.
"DVIM Encrypt"
warning and the caller
and callee of the
failed confirmed call.
The DVIM did not encrypt the
landline-to-radio call.
"MIM Sec Ack"
warning and the caller
and callee of the
failed confirmed call.
A Secondary Acknowledgment
was not received from the MIM
for the landline originated
encrypted Jessica/CTIS call.
"Site Queued"
warning and the caller
and callee of the
failed confirmed call.
The landline originated
encrypted Jessica/CTIS call was
queued at the site.
"Site Sys Busy"
warning and the caller
and callee of the
failed confirmed call.
The landline originated
encrypted Jessica/CTIS call
received a "System Busy" from
the site.
"Site Denied"
warning and the caller
and callee of the
failed confirmed call.
The landline originated
encrypted Jessica/CTIS call was
denied at the site.
W10-018:
TIMEOUT -
CONTROLLER
BOARD
No data, the Node ID
device assignment
and device type fields
of the warning
identify the board.
A Controller Board in the
CEC/IMC did not respond to a poll
from the MOM Controller Board.
The board will be marked as
inactive at the CEC/IMC Manager.
This warning will occur when a
Controller Board is removed from
the CEC/IMC. Other times
indicate a problem with the
reported Controller Board.