Ericsson LBI-39224 Personal Computer User Manual


 
LBI-39224
3-65
PIM "Site" Selection
Prior to actual channel configuration, the interface module to be
configured must be selected. From the CEC/IMC Manager menu bar
select Configure System / CEC/IMC Configuration / PIM to display
the Site Channel Configuration List dialog box for that module.
Each Site Channel Configuration List dialog box displays the
configurable PIMs and configured/active PIMs. A configured and
active PIM represents an operating link between a Jessica PBX
Gateway system and the PIM Controller Board.
Help
Choose the
Help
button to access the Help function. (Help is also
available by pressing the F1 key.)
Configurable Sites:
The Configurable Sites list box displays all inactive unconfigured site-
type interface modules. If a PIM appears in this box, no channel
configuration exists at the CEC/IMC Manager and no active Controller
Board control data link exists at the CEC/IMC for the corresponding
site assignment number. Any number of these available PIMs may be
selected at one time to be assigned to the Configured/Active Sites list
box for configuration.
Configured/Active Sites:
The Configured/Active Sites list box displays PIMs which have been
added but not yet channel-configured, PIMs which have had previous
channel configurations performed, and PIMs which have been
previously channel-configured and have an active Controller Board
control data link. Before a PIM can be channel-configured, it must be
listed in the Configured/Active Sites list box. Any number of these