DEFINITYEnterpriseCommunicationsServerandSystem75andSystem85
Terminals and Adjuncts Reference
555-015-201
Issue 11
December 1999
The 6200 Series Telephones
15-5The 6210 Telephone
15
Distance Limitations
The maximum allowable distances of a 6210 telephone from the DEFINITY G1,
G2, and G3, DEFINITY ECS, System 75, or System 85 cabinet are shown in the
table below.
Power Requirements
The 6210 telephone receives power from the system and does not require any
external power supply.
Switch Administration
The 6210 telephone must be administered in the following ways:
■ If the 6210 telephone is connected to a System 75, a DEFINITY G1 or G3,
or a DEFINITY ECS, it must be administered as a 2500 analog telephone
with Message Waiting
.
■ If the 6210 telephone is connected to a System 85 or a DEFINITY G2, it
can be administered as an analog line.
Power Failure Operation
The 6210 telephone can be used as an emergency station during power failure
transfer conditions.
Table 15-1. Distance Limitations for the 6210 Telephone
System Port Board
Nominal Maximum Range in Feet (Meters)
22 AWG 24 AWG 26 AWG
DEFINITY G2
and
System 85
SN228
SN228B
SN229
12,000 (3,660) 8,000 (2,440) 5,000 (1,525)
DEFINITY G1
and G3,
DEFINITY ECS,
and System 75
TN746B
TN742
TN769
TN746
19,000 (5,795)
3,900 (1,189)
12,000 (3,660)
2,500 (762)
7,500 (2,287)
1,500 (457)