Adjuncts
20-24The 100A Tip/Ring Module
20
Power
The Tip/Ring module will work ONLY if it has auxiliary power. When the auxiliary
power source is turned on, the Tip/Ring module will automatically power up.
Suggested power supplies include:
Suitable stand-alone power supplies include the 1151A1 and the 1151A2
with Battery Holdover.
Suitable bulk power supplies are the 1145A and the 1145B1.
NOTE:
If there is a power outage and the auxiliary power source shuts off, the
telephone will continue to work, but the Tip/Ring module will NOT function.
Administering the Tip/Ring Module
The 6416D+M and 6424D+M telephones are administered as a 6416D+ or
6424D+; however, they MUST BE connected to a DEFINITY ECS Release 6.1 (or
later). In Native Mode the modular 6416D+M and 6424D+M telephones are
administered through a digital line circuit card with a line number (with the usual
three call appearances) assigned to the I-1 Channel. If the 6416D+M or 6424D+M
is connected to a DEFINITY ECS Release 8.1 or later, a second line number can
be administered through the same digital line card on the I-2 Channel, but this line
number can only be used for analog adjuncts connected to the Tip/Ring module.
This analog adjunct is assigned a private number, but can be used only for placing
or terminating a call. It cannot be used for any other analog functions such as
transferring a call or setting up a conference call. If a second line on the telephone
is administered on the I-2-Channel (for analog equipment), type “analog” in the
Data Option field on the administration screen.
On the first station administration screen of the 6416D+ or 6424D+, put a “Y” (for
Yes) next to the “Tip/Ring Module?” entry.
100A Tip/Ring Module PECs and Comcodes
The 100A Tip/Ring Module can be ordered with the following PECs and
Comcodes:
100A-266 Tip/Ring Module
(White) PEC: 3305-TR1, Comcode: 108332446
100A-266Tip/Ring Module with 1151A Power Supply
PEC: 3305-TRP
D2R-87 cord
Comcode: 105001861