Lucent Technologies SYSTEM 85 Server User Manual


 
DEFINITYEnterpriseCommunicationsServerandSystem75andSystem85
Terminals and Adjuncts Reference
555-015-201
Issue 11
December 1999
The 8100 Series Telephones
16-13The 8102 and 8102M Telephones
16
Distance Limitations
The maximum allowable distances of an 8102 or 8102M telephone from the
DEFINITY G1, G2, and G3, DEFINITY ECS, System 75, or System 85 cabinet are
shown in the table below.
Power Requirements
The 8102 and 8102M telephones must have auxiliary power for adjunct
equipment when such equipment is connected.
Switch Administration
The 8102 and 8102M telephones must be administered in the following ways:
If the 8102 or 8102M telephone is connected to a System 75, DEFINITY
G1 or G3, or a DEFINITY ECS, it must be administered as a 2500 analog
telephone with Message Waiting
If the 8102 or 8102M telephone is connected to a System 85 or
DEFINITY G2, it can be administered as an analog line.
NOTE:
The programmable dialing buttons are programmed individually on the
telephone; they are
not
administrable from the switch.
Table 16-2. Distance Limitations for the 8102 and 8102M Telephones
System Port Board
Nominal Maximum Range in Feet
(Meters)
24 AWG 26 AWG
System 85 SN229
SN228B
6,500 (1,981) 4,100 (1,246)
DEFINITY G2 SN229
SN228B
TN742
TN746
6,500 (1,981)
6,500 (1,981)
15,200 (4,633)
3,000 (915)
4,100 (1,246)
4,100 (1,246)
10,000 (3,050)
2,000 (610))
DEFINITY G1
and G3,
DEFINITY ECS,
and System 75
TN742
TN769
TN746
15,200 (4,633)
15,200 (4,633)
3,000 (915)
10,000 (3,050)
10,000 (3,050)
2,000 (610)