Mocomtech CDM-QX Modem User Manual


 
CDM-Qx Satellite Modem Revision 5
Front Panel Operation MN/CDMQx.IOM
5–48
If Upper is selected, the following sub-menu is displayed:
Edit the BUC Current Alarm Upper limit. This is accomplished by selecting the digit to
be edited, using the WXarrow keys. The value of the digit is then changed using the
STarrow keys. The user should then press ENT. The range of current is from 500 to
4000 mA.
If Lower is selected, the following sub-menu is displayed:
Edit the BUC Current Alarm Lower limit. This is accomplished by selecting the digit to
be edited, using the WXarrow keys. The value of the digit is then changed using the
STarrow keys. The user should then press ENT. The range of current is from 100 to
3000 mA.
(ConfigODUBUCDelay) - BUC DELAY
If Delay is selected, the following sub-menu is displayed:
Edit the value of the power-on delay. This is accomplished by selecting the digit to be
edited, using the WXarrow keys. The value of the digit is then changed using the
STarrow keys. The user should then press ENT. The valid range is from 0 to 999
seconds.
BUC Current Alarm Upper
Limit:1200mA ( ,▲▼, ENT)
BUC Power-On Delay:
001 seconds ( ►▲ ENT)
BUC Current Alarm Lower
Limit:1200mA ( ,▲▼, ENT)