Mocomtech CDM-QX Modem User Manual


 
CDM-Qx Satellite Modem Revision 4
Remote Control MN/CDMQx.IOM
C-44
Parameter
Type
Command
(Instruction
Code and
qualifier)
Arguments
for
Command or
Response to
Query
Description of arguments
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to query
(Target to
Controller)
BUC
Temperature
(L-Band Unit
only)
N/A 4 bytes Query only
Indicates BUC temperature, in the form: sxxx
Where:
s=sign (+ or – character)
xx=value
If not available, response is –99
Example: BUT=-13 (BUC temperatures is -13°C)
Note: This query is only valid when the FSK and BUC power
are turned On.
N/A BUT? BUT=sxx
(see description or
arguments)
BUC PLL Alarm
(L-Band Unit
only)
N/A 1 byte, value
of 0,1
Query only
BUC PLL lock state, where:
0=Unlocked
1=Locked
Example: BPA=1 (BUC PLL is locked)
Note: This query is only valid when the FSK and BUC power
are turned On
N/A BPA? BPA=x
(see description of
arguments)
BUC Software
Version
(L-Band Unit
only)
N/A 3 bytes Query only
Indicates the BUC software version, in the form: x.x
Example: BSV=1.1 (Software version 1.1)
Note: This query is only valid when the FSK and BUC power
are turned On
N/A BSV? BSV=x.x
(see description of
arguments)
BUC Current
(L-Band Unit
only)
N/A 4 bytes Query only
Indicates the value of the BUC Current, in the form: xxxx,
where: xxxx is between 0 and 9999, units MA.
If not available, response is 0000
Example: BDC=3100
N/A BDC? BDC=xxxx
(see description of