Mocomtech CDM-QX Modem User Manual


 
CDM-Qx Satellite Modem Revision 5
Front Panel Operation MN/CDMQx.IOM
5–11
(ConfigRemoteSerialInterfaceRS485) - RS-485 Bus
Address
However, if either RS-485 mode is selected, the user will be further prompted:
Edit the RS-485 bus address of this unit. This is accomplished by selecting the digit to be
edited, using the
efarrow keys. The value of the digit is then changed using the
dcarrow keys. The user should then press ENT. The valid range of addresses is from
1 to 9999.
(ConfigRemoteSerialBaudrate)
If the user selects Baud Rate, the user is presented with the following menu:
Edit the baud rate of the remote control bus, connected locally to the M&C computer.
The value is changed using the cdarrow keys. The user should then press ENT. Values
of 2400, 4800, 9600, 19200, 38400, and 57600 baud
are possible.
Note that the asynchronous character format is FIXED at 8 data bits, 1 stop bit, no parity
(8-N-1).
(ConfigRemoteEthernet)
If Ethernet is selected:
M&C Serial Bus Baud Rate:
19200 Baud ( ,ENT)
Edit RS-485 Serial Bus Base
Address: 0245 ( ,▲▼,ENT)
Ethernet Config: ( , ENT)
Gateway Address MAC SNMP