Mocomtech CDM-QX Modem User Manual


 
CDM-Qx Satellite Modem Revision 4
Remote Control MN/CDMQx.IOM
C-41
Parameter
Type
Command
(Instruction
Code and
qualifier)
Arguments
for
Command or
Response to
Query
Description of arguments
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to query
(Target to
Controller)
OGC Outdoor
Unit Global
Configuration
(L-Band Unit
only)
OGC= 50 bytes Command or Query
ODU Global Configuration in the form:
aabcdexxxxhhhiiiijjjjjkxxxxxxlmnnnooopppppqxxxxxx, where:
OGC=
OGC?
OGC*
OGC#
OGC^
OGC? OGC= aabcde
xxxxhhhiiiijjjjjkxxxxxx
lmnnnooopppppqxxx
xxx
(see description of
arguments)
aa=BUC Address
b=BUC FSK comms enable
c=BUC Power Control
d=BUC 10 MHz Freq Ref Enable
e=BUC TX Output Enable
xxxx=expansion bytes
hhhh=BUC Low Alarm Limit
iiii=BUC High Alarm Limit
jjjjjk=BUC LO frequency, mix sign
xxxxxx=expansion bytes
l=LNB Power Control
m=LNB 10 MHz Freq Ref Enable
nnn=LNB Low Alarm Limit
ooo=LNB High Alarm Limit
pppppq=LNB LO Freq, mix sign
xxxxxx=expansion bytes
Any unavailable parameters will be filled
with xxx.
same as BAD
same as BCE
same as BPC
same as BFR
same as BOE
same as BCL
same as BCH
same as BLO
same as LPC
same as LFR
same as LCL
same as LCH
same as LLO
Where: n=0 to 9
Returns the OGC
portion of 1 of 10
stored
configurations
(see description of
arguments)