Mocomtech CDM-QX Modem User Manual


 
CDM-Qx Satellite Modem Revision 4
Remote Control MN/CDMQx.IOM
C-48
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for
Command or
Response to
Query
Description of arguments
Response to
Command
(Target to
Controller)
Query
(Instruction
Code and
Qualifier)
Response to query
(Target to
Controller)
BERT Config
Sync Loss
Threshold
(applies to Rx
card)
BCT= 1 byte, value
of 0 to 3
Command or Query.
BERT config sync loss threshold.
0 = 256 bit errors counted in less than 1000 bits o data
1 = low (100 bit errors in less than 1000 bits of data)
2 = med (250 bit errors in less than 1000 bits of data)
3 = high (20,000 bit errors in less than 100,000 bits of data)
BCT=
BCT?
BCT#
BCT$
BCT^
BCT@
BCT? BCT=x
(see description of
arguments)
BERT Result in
bit errors
(applies to Rx
card)
N/A 7 bytes,
numeric
Query only.
BERT monitor results in bit errors. If bit errors exceed
9999999, then BRE=9999999.
N/A BRE? BRE=xxxxxxx
(see description of
arguments)
BERT Result in
average BER
N/A 5 bytes Query only
Returns the value of the average BER in the form a.b x 10
-c
.
First 3 bytes are the value. Last 2 bytes are the exponent.
Returns 99999 if there’s no sync in BERT monitor. Returns
99.99 if sync loss has occurred.
Example: BER=4.8E3 (BER = 4.8 x 10
-3
)
N/A BRR? BRR=a.bEc
(see description of