Mocomtech CDM-QX Modem User Manual


 
CDM-Qx Satellite Modem Revision 5
Front Panel Operation MN/CDMQx.IOM
5–60
5.6.2.7 (MonitorODU) – MONITOR ODU (for L-Band Unit only)
If ODU is selected, the following sub-menu is displayed:
If BUC is selected, the following menu is displayed:
The menu displays the following parameters:
DC Pwr
(DC Power) If a BUC supply is installed, displays
measured BUC supply voltage and load current,
measured at the Tx-IF connector.
T
(Temperature) If BUC FSK is enabled, displays
BUC ambient temperature in °C.
SW
If BUC FSK is enabled, displays the M&C
software version of the BUC.
PLL
If BUC FSK is enabled, displays the fault status of
the BUC PLL synthesizers.
Pwr
(Output) If BUC FSK is enabled, displays the
output power as measured by the BUC power
monitor.
Press ENT or CLR to return to the next-highest menu.
Select LNB or BUC, using the arrow keys, then press ENT.
If LNB is selected, the following menu is displayed:
The menu displays the LNB Voltage and Current. Press ENT or CLR to return to the
next-highest menu.
Outdoor Unit Monitor:
ODU LNB ( , ENT)
BUC: DC=47.8V,3.2A T=38
o
C
SW=1.1 PLL=Flt Pwr=02.1W
LNB Voltage: 13.1 volts
LNB Current: 235 mA (ENT)